Base Model | CS | CSmicro | CSmicro 2W | CSmicro 2W | CSmicro 2W | | |
Type | LT | LT02 / LT15 / 3M | LT15 / LT15H / LT22H | hs LT | 2M | | |
Classification / | Single-piece sensor | Single-piece sensor with | Single-piece two-wire | Single-piece two-wire | Single-piece two-wire | | |
special features | with smart LED display | electronics in cable and | sensor with electronics in | sensor with electronics in | sensor with electronics | | |
| (self diagnostics, | smart LED display | cable; smart LED display | cable with high thermal | in applications; | | |
| aiming support, alarm, | (aiming support, alarm, | (aiming support, alarm, | sensitivity; smart LED | smart LED display; | | |
| temperature code) | temperature code) | temperature code) | display; temperature code | temperature code | | |
Detector | Thermopile | Thermopile / 3M: Ext. InGaAs | Thermopile | Thermopile | InGaAs | | |
Sensing head exchangeable | – | – | – | – | – | | |
Head cable shortening | ■ | ■ (behind electronics) | ■ (behind electronics) | ■ (behind electronics) | ■ (behind electronics) | | |
Thread (sensing head) | M12x1 | M12x1 | M12x1 | M18x1 | M12x1 | | |
Spectral range | 8 – 14 μm | 8 – 14 μm / 3M: 2.3 μm | 8 – 14 μm | 8 – 14 μm | 1.6 μm | | |
Temperature ranges | –40 °C ... 1030 °C | –40 °C ... 1030 °C | –40 °C ... 1030 °C | –20 °C ... 150 °C | 2ML: 250 °C ... 800 °C | | |
| | 3ML: 50 °C ... 350 °C | | | 2MH: 385 °C ... 1600 °C | | |
| | 3MH: 100 °C ... 600 °C | | | | | |
Temperature resolution | 0.1 K | 0.1 K | 0.1 K | 0.025 K [>20 °C] | 0.1 K | | |
Optical resolution | 15:01 | LT02: 2:1 / LT15: 15:1 / | LT15: 15:1 / LT15H: 15:1 / | 15:01 | 2ML: 40:1 | | |
| | 3ML: 22:1 / 3MH: 33:1 | LT22H: 22:1 | | 2MH: 75:1 | | |
Option: CF lens | ■ | ■ | ■ | ■ | ■ | | |
Smallest spot (CF optics / add. CF lens) | 0.8 mm @ 10 mm | LT02: 2.5 mm @ 23 mm | LT15: 0.8 mm @ 10 mm | 0.8 mm @ 10 mm | 2MH: 1.5 mm@110 mm | | |
| | LT15: 0.8 mm @ 10 mm | LT15H: 0.8 mm @ 10 mm | | 2ML: 2.7 mm@110 mm | | |
| | 3M: 1.5 mm @ 10 mm | LT22H: 0.6 mm @ 10 mm | | | | |
Smallest spot (SF optics) | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | | |
Sighting | LED aiming | LED aiming | LED aiming | LED aiming | LED aiming | | |
Response time (90 %) | 25 ms | 30 ms | LT: 30 ms / LTH: 150 ms | 150 ms | 10 ms | | |
Accuracy | ±1.5 °C or ±1.5 % | ±1.5 °C or ±1.5 % | ±1.5 °C or ±1 % | ±1 °C or ±1 % | ±(0.3 % Tmeas +2 °C) | | |
Outputs analog: 0 – 20 mA / | – / – / ■ / ■ / ■ | – / – / ■ / ■ / – | – / ■ / – / – / – | – / ■ / – / – / – | – / ■ / – / – / – | | |
4 – 20 mA / 0 – 5 V / 0 – 10 V / t/c (K/J) | | | | | | | |
Second analog output | – | – | – | – | – | | |
Interfaces: USB / RS232 / | ■ / – / – / – / – | ■ / – / – / – / – | ■ / – / – / – / – | ■ / – / – / – / – | ■ / – / – / – / – | | |
RS485 / Profibus / Ethernet | | | | | | | |
Signal processing: | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | | |
Peak / Valley / AVG / Advanced hold | | | | | | | |
TAmb Head min. | –20 °C | –20 °C | –20 °C | –20 °C | –20 °C | | |
TAmb Head max. | 80 °C | LT02 / LT15: 120 °C | LT15: 120 °C | 75 °C | 125 °C | | |
| | 3M: 85 °C | LT15H / LT22H: 180 °C | | | | |
TAmb Electronics max. | 80 °C | 80 °C | 75 °C | 75 °C | 75 °C | | |
Functional inputs / number | ■ / 1 | ■ / 1 | – / – | – / – | – / – | | |
External emissivity adjustment | ■ (via Vcc adjust) | ■ (via Vcc adjust) | – | – | – | | |
External background temperature control | ■ | ■ | – | – | – | | |
Trigger input for reset of hold functions | ■ | ■ | – | – | – | | |
Digital I/O pins / number | – | – | – | – | – | | |
Simultaneous analog and digital output | – | – | ■ | ■ | ■ | | |
Alarm output as an alternative to analog output | ■ | ■ | ■ | ■ | ■ | | |
Additional alarm output / switching output | ■ | ■ | ■ | ■ | ■ | | |
Voltage supply | 5 – 30 V DC | 5 – 30 V DC | 5 – 30 V DC | 5 – 30 V DC | 5 – 30 V DC | | |
Standard cable length | 1 m | 1 m | 1 m | 4 m | 1 m | | |
Cable length options | 3 / 8 / 15 m | Options up to 9 m | Options up to 9 m | – | Options up to 9 m | | |
| | | | | | | |
CT | CTfast | CThot | CT | CT | CT | CT | |
LT02 / LT15 / LT22 | LT15F / LT25F | LT02H / LT10H | 1M / 2M | 3M | G5 | P7 | |
Two-piece sensor with | Two-piece sensor with | Two-piece sensor for | Two-piece sensor for high | Two-piece sensor for low | Two-piece sensor for | Two-piece sensor for | |
separate electronic box | fast response time and | hot surroundings with | temp. meas. of metal | temp. meas. of metal | temp. meas. of glass | temp. meas. on plastic foils | |
incl. programming keys | separate electronic box | separate electronic box | with separate electronic | with separate electronic | with separate electronic | and glass with separate | |
and display | incl. programming keys | incl. programming keys | box incl. progr. keys and | box incl. progr. keys and | box incl. progr. keys and | electronic box incl. progr. | |
| and display | and display | display | display | display | keys and display | |
Thermopile | Thermopile | Thermopile | 1M: Si / 2M: InGaAs | Extended InGaAs | Thermopile | Thermopile | |
■ | – | – | ■ [+CTlaser 1M/2M] | ■ [+CTlaser 3M] | ■ | – | |
■ [–0.1 K/m] | ■ [max. 3 m] | ■ [–0.1 K/m] | ■ [max. 3 m] | ■ | ■ [–0.1 K/m] | – | |
M12x1 | M12x1 | M18x1 | M12x1 | M12x1 | M12x1 | M18x1 | |
8 – 14 μm | 8 – 14 μm | 8 – 14 μm | 1M: 1.0 μm / 2M: 1.6 μm | 2.3 μm | 5.0 μm | 7.9 μm | |
LT02: –50 °C ... 600 °C | –50 °C ... 975 °C | –40 °C ... 975 °C | 1ML: 485 °C ... 1050 °C | L: 50 °C ... 400 °C | L: 100 °C ... 1200 °C | 0 °C ... 710 °C | |
LT15: –50 °C ... 600 °C | | | 1MH: 650°C ... 1800 °C | H: 100 °C ... 600 °C | H: 250 °C ... 1650 °C | | |
LT22: –50 °C ... 975 °C | | | 1MH1: 800 °C ... 2200 °C | H1: 150 °C ... 1000 °C | | | |
| | | 2ML: 250 °C ... 800 °C | H2: 200 °C ... 1500 °C | | | |
| | | 2MH: 385 °C ... 1600 °C | H3: 250 °C ... 1800 °C | | | |
| | | 2MH1: 490 °C ... 2000 °C | | | | |
0.1 K | LT15F: 0.2 K | 0.25 K | 0.1 K | 0.1 K | L: 0.1 K | 0.5 K | |
| LT25F: 0.4 K | | | | H: 0.2 K | | |
LT02: 2:1 / LT15: 15:1 / | LT15F: 15:1 | LT02H: 2:1 | L: 40:1 | L: 22:1 / H: 33:1 / | L: 10:1 | 10:01 | |
LT22: 22:1 | LT25F: 25:1 | LT10H: 10:1 | H: 75:1 | H1–H3: 75:1 | H: 20:1 | | |
■ | ■ | ■ | ■ | ■ | – | – | |
LT02: 2.5 mm @ 23 mm | 0.6 mm @ 10 mm | LT02H: 2.5 mm @ 23 mm | 1.5 mm @ 110 mm | 3.4 mm @ 110 mm | – | 1.2 mm @ 10 mm | |
LT15: 0.8 mm @ 10 mm | | LT10H: 1.2 mm @ 10 mm | | | | | |
LT22: 0.6 mm @ 10 mm | | | | | | | |
7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | |
– | – | – | – | – | – | – | |
150 ms | LT15F: 9 ms / LT25F: 6 ms | 100 ms | 1 ms | 1 ms | L: 120 ms / H: 80 ms | 150 ms | |
±1 °C or ±1 % | ±2 °C or ±1 % | ±1.5 °C or ±1 % | ±(0.3 % Tmeas +2 °C) | ±(0.3 % Tmeas +2 °C) | ±2 °C or ±1 % | ±1.5 °C or ±1 % | |
■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | |
■ | ■ | ■ | – | – | ■ | ■ | |
■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | |
■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | |
–20 °C | –20 °C | –20 °C | –20 °C | –20 °C | –20 °C | –20 °C | |
LT02: 130 °C | 120 °C | 250 °C | 1M: 100 °C | 85 °C | 85 °C | 85 °C | |
LT15 / LT22: 180 °C | | | 2M: 125 °C | | | | |
85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
– | – | – | – | – | – | – | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | |
1 m | 1 m | 3 m | 3 m | 3 m | 3 m | 3 m | |
3 / 8 / 15 m | 3 / 8 / 15 m | 8 / 15 m | 8 / 15 m | – | 8 / 15 m | 8 / 15 m | |
| | | | | | | |
Base Model | CSlaser | CSlaser | CSlaser | CTlaser | CTlaser | | |
Type | LT / hs LT | 2M | G5HF | LT / LTF | 05M | | |
Classification / | Single-piece two-wire | Single-piece two-wire | Single-piece two-wire | Two-piece sensor with | Two-piece sensor with | | |
special features | sensor with electronics | sensor with electronics | infrared thermometer | separate electronic | separate electronic | | |
| in sensing head | in sensing head for | for temperature | box with fast response | box for high temp. | | |
| | measurement of metal | measurement of glass | time, incl. programming | measurement of liquid | | |
| | | | keys and display | metal, incl. programming | | |
| | | | | keys and display | | |
Detector | Thermopile | InGaAs | Thermopile | Thermopile | Si | | |
Sensing head exchangeable | – | – | – | ■ | ■ | | |
Head cable shortening | ■ | ■ | ■ | ■ [max. 6 m] | ■ [max. 6 m] | | |
Thread (sensing head) | M48x1.5 | M48x1.5 | M48x1.5 | M48x1.5 | M48x1.5 | | |
Spectral range | 8 – 14 μm | 1.6 μm | 5.0 μm | 8 – 14 μm | 0.525 μm | | |
Temperature ranges | LT: –30 °C ... 1000 °C | L: 250 °C ... 800 °C | 200 ... 1650 °C | –50 °C ... 975 °C | 1000 °C ... 2000 °C | | |
| hs LT: –20 °C ... 150 °C | H: 385 °C ... 1600 °C | | | | | |
Temperature resolution | LT: 0.1 K / hs LT: 0.025 K | 0.1 K | 0.1 K | LT: 0.1 K / LTF: 0.5 K | 0.2 K | | |
Optical resolution | 50:01:00 | 300:01:00 | 45:01:00 | LT: 75:1 | 150:01:00 | | |
| | | | LTF: 50:1 | | | |
Option: CF lens | – | – | – | – | – | | |
Smallest spot (CF optics / add. CF lens) | 1.4 mm @ 70 mm | 0.5 mm @ 150 mm | 1.6 mm @ 70 mm | LT: 0.9 mm @ 70 mm | – | | |
| | | | LTF: 1.4 mm @ 70 mm | | | |
Smallest spot (SF optics) | 24 mm @ 1200 mm | 3.7 mm @ 1100 mm | 27 mm @ 1200 mm | LT: 16 mm @ 1200 mm | 7.3 mm @ 1100 mm | | |
| | | | LTF: 24 mm @ 1200 mm | | | |
Sighting | Double laser | Double laser | Double laser | Double laser | Double laser | | |
Response time (90 %) | 150 ms | 10 ms | 30 ms | LT: 120 ms / LTF: 9 ms | 1 ms | | |
Accuracy | ±1 °C or ±1 % | ±(0.3 % Tmeas +2 °C) | ±1% or ±1°C | LT: ±1 °C or ±1 % | ±(0.3 % Tmeas +2 °C) | | |
| | | | LTF: ±1.5 °C or ±1.5 % | | | |
Outputs analog: 0 – 20 mA / | – / ■ / – / – / – | – / ■ / – / – / – | – / ■ / – / – / – | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | | |
4 – 20 mA / 0 – 5 V / 0 – 10 V / t/c (K/J) | | | | | | | |
Second analog output | – | – | – | ■ | – | | |
Interfaces: | ■ / – / – / – / – | ■ / – / – / – / – | ■ / – / – / – / – | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | | |
USB / RS232 / RS485 / Profibus / Ethernet | | | | | | | |
Signal processing: | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | | |
Peak / Valley / AVG / Advanced hold | | | | | | | |
TAmb Head min. | –20 °C | –20 °C | –20 °C | –20 °C | –20 °C | | |
TAmb Head max. | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | | |
TAmb Electronics max. | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | | |
Functional inputs / number | – / – | – / – | – / – | ■ / 3 | ■ / 3 | | |
External emissivity adjustment | – | – | – | ■ | ■ | | |
External background temperature control | – | – | – | ■ | ■ | | |
Trigger input for reset of hold functions | – | – | – | ■ | ■ | | |
Digital I/O pins / number | – | – | – | – | – | | |
Simultaneous analog and digital output | ■ | ■ | ■ | ■ | ■ | | |
Alarm output as alternative to analog output | ■ | ■ | ■ | ■ | ■ | | |
Additional alarm output / switching output | ■ | ■ | ■ | ■ | ■ | | |
Voltage supply | 5 – 30 V DC | 5 – 30 V DC | 5 – 28 V DC | 8 – 36 V DC | 8 – 36 V DC | | |
Standard cable length | 3 m | 3 m | 3 m | 3 m | 3 m | | |
Cable length options | 8 / 15 m | 8 / 15 m | 3 m / 8 m / 15 m | 8 / 15 m | 8 / 15 m | | |
| | | | | | | |
CTlaser | CTlaser | CT XL | CTlaser | CTlaser | CTlaser | CTratio | |
1M / 2M | 3M | 3M | MT / F2 / F6 | G5 | P7 | 1M | |
Two-piece sensor with | Two-piece sensor with | Two-piece sensor with | Two-piece sensor with | Two-piece sensor with | Two-piece sensor with | Ratio pyrometer with | |
separate electronic | separate electronic | separate electronic box | separate electronic box | separate electronic box | separate electronic | separate electronic box | |
box for high temp. | box for low temp. | for laser applications, | incl. progr. keys and | for measurement of | box for measurement | for high temp. measure- | |
measurement of metal, | measurement of metal, | incl. programming keys | display for measurement: | glass, incl. programming | of plastic foils, incl. | ment of metal feat. | |
incl. programming keys | incl. programming keys | and display (no laser) | MT: through flames | keys and display | programming keys and | glass fiber cable and | |
and display | and display | | F2: CO2 flame gas | | display | laser, incl. programming | |
| | | F6: CO flame gas | | | keys and display | |
1M: Si / 2M: InGaAs | Extended InGaAs | Extended InGaAs | Thermopile | Thermopile | Thermopile | Si sandwich | |
■ [+CT 1M / 2M] | ■ [+CT 3M] | – | ■ | ■ | ■ | – | |
■ [max. 6 m] | ■ [max. 6 m] | ■ | ■ [max. 6 m] | ■ [max. 6 m] | ■ [max. 6 m] | – | |
M48x1.5 | M48x1.5 | M30x1 | M48x1.5 | M48x1.5 | M48x1.5 | M18x1 | |
1M: 1.0 μm | 2.3 μm | 2.3 μm | MT: 3.9 μm / F2: 4.24 μm / | 5.0 μm | 7.9 μm | 0.7 – 1.1 μm | |
2M: 1.6 μm | | | F6: 4.64 μm | | | | |
1ML: 485 °C ... 1050 °C | L: 50 °C ... 400 °C | H: 100 °C ... 600 °C | 200 °C ... 1650 °C | L: 100 °C ... 1200 °C | 0 °C ... 710 °C | 700 °C ... 1800 °C | |
1MH: 650 °C ... 1800 °C | H: 100 °C ... 600 °C | H1: 150 °C ... 1000 °C | | H: 250 °C ... 1650 °C | | | |
1MH1: 800 °C ... 2200 °C | H1: 150 °C ... 1000 °C | H2: 200 °C ... 1500 °C | | HF: 200 °C ... 1650 °C | | | |
2ML: 250 °C ... 800 °C | H2: 200 °C ... 1500 °C | H3: 250 °C ... 1800 °C | | | | | |
2MH: 385 °C ... 1600 °C | H3: 250 °C ... 1800 °C | | | | | | |
2MH1: 490 °C ... 2000 °C | | | | | | | |
0.1 K | 0.1 K | 0.1 K | 0.1 K | L: 0.1 K / H,HF: 0.2 K | 0.5 K | 0.1 K (> 900 °C) | |
L: 150:1 | L: 60:1 / H: 100:1 / | H: 100:1 | 45:01:00 | L/HF: 45:1 | 45:01:00 | 40:01:00 | |
H: 300:1 | H1-H3: 300:1 | H1-H3: 300:1 | | H: 70:1 | | | |
– | – | – | – | – | – | – | |
0.5 mm @ 150 mm | 0.5 mm @ 150 mm | 0.5 mm @ 150 mm | 1.6 mm @ 70 mm | 1 mm @ 70 mm | 1.6 mm @ 70 mm | 7.7 mm @ 305 mm | |
3.7 mm @ 1100 mm | 11 mm @ 1100 mm | 11 mm @ 1100 mm | 27 mm @ 1200 mm | 17 mm @ 1200 mm | 27 mm @ 1200 mm | 31.3 mm @ 1143 mm | |
Double laser | Double laser | – | Double laser | Double laser | Double laser | Laser | |
1 ms | 1 ms | 1 ms | 10 ms | L: 120 ms / H: 80 ms | 150 ms | 5 ms | |
| | | | HF: 10 ms | | | |
±(0,3 % Tmeas +2 °C) | ±(0.3 % Tmeas +2 °C) | ±(0.3 % Tmeas +2 °C) | ±1.5 °C or ±1 % | ±1.5 °C or ±1 % | ±1.5 °C or ±1 % | ±(0.5 % Tmeas +1 °C) | |
■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / – | |
– | – | – | ■ | ■ | ■ | – | |
■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | – / – / – / – / – | |
■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | |
–20 °C | –20 °C | –20 °C | –20 °C | –20 °C | –20 °C | –20 °C | |
85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 250 °C | |
85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | ■ / 3 | – / – | |
■ | ■ | ■ | ■ | ■ | ■ | – | |
■ | ■ | ■ | ■ | ■ | ■ | – | |
■ | ■ | ■ | ■ | ■ | ■ | ■ (via I/O pins) | |
– | – | – | – | – | – | ■ / 2 | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
■ | ■ | ■ | ■ | ■ | ■ | ■ | |
■ | ■ | ■ | ■ | ■ | ■ | ■ (via I/O pins) | |
8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | 8 – 36 V DC | |
3 m | 3 m | 3 m | 3 m | 3 m | 3 m | 3 m | |
8 / 15 m | 8 / 15 m | – | 8 / 15 m | 8 / 15 m | 8 / 15 m | 6 / 10 / 15 / 22 m | |
| | | | | | | |
Base Modell | CSvideo | CTvideo | CTvideo | | | | |
Type | 2M (L / H) | 1M / 2M (L / H) | 3M (L / H) | | | | |
Classification / | Single-piece two wire sensor with | Two-piece sensor with electronic box for | Two-piece sensor with electronic box for | | | | |
special features | electronics in sensing head, video camera | high temperature measurement of metals, | low temperature measurement of metals, | | | | |
| and cross hair laser for measuring metal | video camera and cross hair laser | video camera and cross hair laser | | | | |
Detector | InGaAs | 1M: Si / 2M: InGaAs | Extended InGaAs | | | | |
Sensing head exchangeable | – | [+CT 1M / 2M] | [+CT 3M] | | | | |
Head cable shortening | ■ | [max. 6 m] | [max. 6 m] | | | | |
Thread (sensing head) | M48x1.5 | M48x1.5 | M48x1.5 | | | | |
Spectral range | 1.6 μm | 1M: 1.0 μm / 2M: 1.6 μm | 2.3 μm | | | | |
Temperature ranges | 250 °C ... 800 °C (2ML) | 485 °C ... 1050 °C (1ML) | 50 °C ... 400 °C (3ML) | | | | |
(scalable via software) | 385 °C ... 1600 °C (2MH) | 650 °C ... 1800 °C (1MH) | 100 °C ... 600 °C (3MH) | | | | |
| | 800 °C ... 2200 °C (1MH1) | 150 °C ... 1000 °C (3MH1) 1) | | | | |
| | 250 °C ... 800 °C (2ML) | 200 °C ... 1500 °C (3MH2) 1) | | | | |
| | 385 °C ... 1600 °C (2MH) | 250 °C ... 1800 °C (3MH3) 1) | | | | |
| | 490 °C ... 2000 °C (2MH1) | | | | | |
Temperature resolution | 0.1 K | ML: 0.1 K / MH: 0.2 K | 0.1 K | | | | |
Optical resolution | 2MH: 300:1 / 2ML: 150:1 | L: 150:1 / H: 300:1 | L: 60:1 / H: 100:1 / H1 – H3: 300:1 | | | | |
Smallest spot (CF optics) | 2ML: 0.6 mm @ 90 mm (CF) | 1ML/2ML: 0.6 mm @ 90 mm (CF) | 3ML: 1.5 mm @ 90 mm (CF) | | | | |
CF vario optics: focusable from | 2MH: 0.3 mm @ 90 mm (CF) | 1MH-H1/ 2MH-H1: 0.3 mm @ 90 mm (CF) | 3MH: 0.9 mm @ 90 mm (CF) | | | | |
90 mm to 250 mm | | | 3MH1 – H3: 0.3 mm @ 90 mm (CF) | | | | |
Smallest spot (SF optics) | 2ML: 1.3 mm @ 200 mm (SF) | 1ML/2ML: 1.3 mm @ 200 mm (SF) | 3MH: 3.3 mm @ 200 mm (SF) | | | | |
SF vario optics: focusable from | 2MH: 0.7 mm @ 200 mm (SF) | 1MH-H1/ 2MH-H1: 0.7 mm @ 200 mm (SF) | 3MH: 2.0 mm @ 200 mm (SF) | | | | |
200 mm to infinity | | | 3MH1 – H3: 0.7 mm @ 200 mm (SF) | | | | |
Sighting | video camera and cross hair laser | video camera and cross hair laser | video camera and cross hair laser | | | | |
Response time (90 %) | 10 ms | 1 ms | 1 ms | | | | |
Accuracy | ±(0.3 % Tmeas +2 °C) | ±(0.3 % Tmeas +2 °C) | ±(0.3 % Tmeas +2 °C) | | | | |
Outputs analog: 0 – 20 mA / | – / ■ / – / – / – | ■ / ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ / ■ | | | | |
4 – 20 mA / 0 – 5 V / 0 – 10 V / t/c (K/J) | | | | | | | |
Interfaces: USB / RS232 / | ■ / – / – / – / ■ | ■ / – / – / – / ■ | ■ / – / – / – / ■ | | | | |
RS485 / Profibus / Ethernet | | | | | | | |
Signal processing: | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | ■ / ■ / ■ / ■ | | | | |
Peak / Valley / AVG / Advanced hold | | | | | | | |
TAmb Head min. | –20 °C | –20 °C | –20 °C | | | | |
TAmb Head max. | 70 °C | 85 °C | 85 °C | | | | |
TAmb Electronics max. | 70 °C | 85 °C | 85 °C | | | | |
Functional inputs / number | – / – | ■ / 3 | ■ / 3 | | | | |
External emissivity adjustment | – | ■ | ■ | | | | |
External background temperature | – | ■ | ■ | | | | |
control | | | | | | | |
Trigger input for reset of hold | – | ■ | ■ | | | | |
functions | | | | | | | |
Simultaneous analog and digital | ■ | ■ | ■ | | | | |
output | | | | | | | |
Alarm output as an alternative to | ■ | ■ | ■ | | | | |
analog output | | | | | | | |
Additional alarm output | 0 – 30 V / 500 mA (open-collector) | 24 V / 50 mA (open-collector) | 24 V / 50 mA (open-collector) | | | | |
Voltage supply | 5 – 28 V DC | 8 – 36 V DC | 8 – 36 V DC | | | | |
Standard cable length | 3 m | 3 m | 3 m | | | | |
Cable length options | 8 / 15 m | 5 / 10 m | 5 / 10 m | | | | |
| | | | | | | |
Base Model | PI 160 | PI 200 / PI 230 | PI 400 / PI 450 | | | |
Type | | IR | BI-SPECTRAL | IR | | | |
Detector | | FPA, uncooled (25 μm x 25 μm) | FPA, uncooled (25 μm x 25 μm) | FPA, uncooled (25 μm x 25 μm) | | | |
Optical resolution | 160 x 120 pixel | 160 x 120 pixel | 382 x 288 pixel | | | |
Spectral range | | 7.5 – 13 μm | 7.5 – 13 μm | 7.5 – 13 μm | | | |
Temperature ranges | –20 °C ... 100 °C, 0 °C ... 250 °C, | –20 °C ... 100 °C, 0 °C ... 250 °C, | –20 °C ... 100 °C, 0 °C ... 250 °C, | | | |
| | 150 °C ... 900 °C, additional range: | 150 °C ... 900 °C, additional range: | 150 °C ... 900 °C, additional range: | | | |
| | 200 °C ... 1500 °C (option) * | 200 °C ... 1500 °C (option) * | 200 °C ... 1500 °C (option for PI 400) | | | |
Frame rate | | 120 Hz | 128 Hz *** | 80 Hz | | | |
Optics (FOV) | | 23° x 17° / f = 10 mm or | 23° x 17° ** / f = 10 mm or | 38° x 29° / f = 15 mm or | | | |
| | 6° x 5° / f = 35.5 mm or | 6° x 5° / f = 35.5 mm or | 13° x 10° / f = 41 mm or | | | |
| | 41° x 31° / f = 5.7 mm or | 41° x 31° ** / f = 5.7 mm or | 62° x 49° / f = 11 mm or | | | |
| | 72° x 52° / f = 3.3 mm | 72° x 52° / f = 3.3 mm | 80° x 56° / f = 7.7 mm | | | |
Thermal sensitivity | 0.08 K with 23° x 17° FOV / F = 0.8 | 0.08 K with 23° x 17° FOV / F = 0.8 | PI 400: 0.08 K | | | |
(NETD) | | 0.3 K with 6° x 5° FOV / F = 1.6 | 0.3 K with 6° x 5° FOV / F = 1.6 | PI 450: 0.04 K with 38° x 29° FOV / F = 0.8 | | | |
| | 0.1 K with 41° x 31° FOV and | 0.1 K with 41° x 31° FOV and | PI 400: 0.08 K | | | |
| | 72° x 52° FOV / F = 1 | 72° x 52° FOV / F = 1 | PI 450: 0.04 K with 62° x 49° FOV / F = 0.8 | | | |
| | | | PI 400: 0.1 K | | | |
| | | | PI 450: 0.06 K with 13° x 10° FOV / F = 1.0 | | | |
Option for visual camera | – | Optical resolution: 640 x 480 pixel | – | | | |
(only for BI-SPECTRAL | | Frame rate: 32 Hz *** | | | | |
camera) | | | Optics (FOV): PI 200: 54° x 40°, | | | | |
| | | PI 230: 30° x 23° | | | | |
Accuracy | | ±2 °C or ±2 %, whichever is greater | ±2 °C or ±2 %, whichever is greater | ±2 °C or ±2 %, whichever is greater | | | |
PC interface | | USB 2.0 | USB 2.0 | USB 2.0 | | | |
Process | Standard PIF | 0 – 10 V input, digital input (max. 24 V), | 0 – 10 V input, digital input (max. 24 V), | 0 – 10 V input, digital input (max. 24 V), | | | |
interface | | 0 – 10 V output | 0 – 10 V output | 0 – 10 V output | | | |
(PIF) | Industrial PIF | 2 x 0 – 10 V inputs, digital input (max. 24 V), | | 2 x 0 – 10 V inputs, digital input (max. 24 V), | | | |
| (option) | 3 x 0 – 10 V outputs, | | 3 x 0 – 10 V outputs, | | | |
| | 3 x relay (0 – 30 V / 400 mA), fail-safe relay | | 3 x relay (0 – 30 V / 400 mA), fail-safe relay | | | |
Ambient temperature (TAmb) | 0 °C ... 50 °C | 0 °C ... 50 °C | PI 400: 0 °C ... 50 °C / PI 450: 0 °C ... 70 °C | | | |
Storage temperature | – 40 °C ... 70 °C | – 40 °C ... 70 °C | PI 400: – 40 °C ... 70 °C | | | |
| | | | PI 450: – 40 °C ... 85 °C | | | |
Relative humidity | 20 – 80 %, non-condensing | 20 – 80 %, non-condensing | 20 – 80 %, non-condensing | | | |
Housing (size / rating) | 45 mm x 45 mm x 62 mm / IP 67 (NEMA 4) | 45 mm x 45 mm x 62 mm / IP 67 (NEMA 4) | 46 mm x 56 mm x 90 mm / IP 67 (NEMA 4) | | | |
Weight | | 195 g, incl. lens | 215 g, incl. lens | 320 g, incl. lens | | | |
Shock / vibration | Shock: IEC 60068-2-27 (25 g and 50 g) | Shock: IEC 60068-2-27 (25 g and 50 g) | Shock: IEC 60068-2-27 (25 g and 50 g) | | | |
| | Vibration: IEC 60068-2-6 (sinus-shaped)/ | Vibration: IEC 60068-2-6 (sinus-shaped)/ | Vibration: IEC 60068-2-6 (sinus-shaped)/ | | | |
| | IEC 60068-2-64 (broadband noise) | IEC 60068-2-64 (broadband noise) | IEC 60068-2-64 (broadband noise) | | | |
Tripod mount | | ¼ -20 UNC | ¼ - 20 UNC | ¼ - 20 UNC | | | |
Voltage supply | | via USB | via USB | via USB | | | |
Scope of supply (standard) | • USB camera with 1 lens | • USB camera with 1 lens and | • USB camera with 1 lens | | | |
| | • USB cable (1 m) | BI-SPECTRAL technology | • USB cable (1 m) | | | |
| | • Table-top tripod | • USB cable (1 m) | • Table-top tripod | | | |
| | • PIF cable with connecting terminal strip (1 m) | • Table-top tripod | • PIF cable with connecting terminal strip (1 m) | | | |
| | • optris® PI Connect software package | • Focus tool | • optris® PI Connect software package | | | |
| | • Aluminium case | • PIF cable with connecting terminal strip (1 m) | • Aluminium case (PI400) | | | |
| | | • optris® PI Connect software package | • Robust hard shell case (PI 450) | | | |
| | | • Aluminium case | | | | |
| | | | |
* The additional range is not available for 72° HFOV optics | ** For ideal combination of IR and VIS image, a 41° HFOV lens is | | | |
| | | recommended (PI 200). For the PI 230, a 23° lens is recommended. | | | |
| | | | | | | |
Base Model | LS | P20 | P20 | MS | MSPlus | MSPro | |
Type | LT | LT | 1M / 2M / 05M | LT | LT | LT | |
Detector | Thermopile | Thermopile | Si / InGaAs | Thermopile | Thermopile | Thermopile | |
Spectral range | 8 – 14 μm | 8 – 14 μm | 1M: 1.0 μm | 8 – 14 μm | 8 – 14 μm | 8 – 14 μm | |
| | | 2M: 1.6 μm | | | | |
| | | 05M: 525 nm | | | | |
Temperature ranges | –35 °C ... 900 °C | 0 °C ... 1300 °C | 1M: 650 °C ... 1800 °C | –32 °C ... 420 °C | –32 °C ... 530 °C | –32 °C ... 760 °C | |
| | | 2M: 385 °C ... 1600 °C | | | | |
| | | 05M: | | | | |
| | | 1000 °C ... 2000 °C | | | | |
Temperature resolution | 0,1 K | 1 K | 1 K | 0.2 K | 0.1 K | 0.1 K | |
Optical resolution | 75:01:00 | 120:01:00 | 1M / 2M: 300:1 | 20:01 | 20:01 | 40:01:00 | |
| | | 05M: 150:1 | | | | |
Switchable optics | ■ | – | – | – | – | – | |
Smallest spot | 1 mm @ 62 mm | – | – | – | – | – | |
(CF optics) | | | | | | | |
Smallest spot | 16 mm @ 1200 mm | 100 mm @ 12 m | 1M / 2M: | 13 mm @ 140 mm | 13 mm @ 140 mm | 13 mm @ 260 mm | |
(SF optics) | | | 12 mm @ 3.6 m | | | | |
| | | 05M: 24 mm @ 3.6 m | | | | |
Sighting | Cross hair laser | Double laser | Double laser | Laser | Laser | Laser | |
Response time (90 %) | 150 ms | 300 ms | 100 ms | 300 ms | 300 ms | 300 ms | |
Accuracy | ±0,75 % (100 to 900 °C) | ±2 °C or ±1 % | ±(0.3 % Tmeas +2 °C) | ±1 °C or ±1 % | ±1 °C or ±1 % | ±1 °C or ±1 % | |
(at TAmb 23 ± 5 °C) | ±0,75 °C (20 to 99,9 °C) | | | | | | |
±1,5 °C (-20 to 19,9 °C) | | | | | | |
| | | | | | |
| ±2,5 °C (-35 to -20,1 °C) | | | | | | |
PC interface | USB | USB | USB | USB | USB | USB | |
Software | ■ | ■ | ■ | ■ | ■ | ■ | |
Probe connection (t/c) | ■ | – | – | – | – | ■ | |
TAmb Min. / Max. | 0 °C / 50 °C | 0 °C / 50 °C | 0 °C / 50 °C | 0 °C / 50 °C | 0 °C / 50 °C | 0 °C / 50 °C | |
Display | ■ | ■ | ■ | ■ | ■ | ■ | |
MAX / MIN / HOLD | ■ | ■ | ■ | – | ■ | ■ | |
HIGH / LOW alarm | |
Data logger / capacity | ■ / 100 | ■ / 2000 | ■ / 2000 | – | – | ■ / 20 | |
Emissivity | 0.100 ... 1.100 | 0.100 ... 1.100 | 0.100 ... 1.100 | 0.95 fixed | 0.100 ... 1.100 | 0.100 ... 1.100 | |
| | | | | | | |