IMPULSE WINDING TESTER ST4030A

(1 đánh giá)

Mã SP: ST4030A

Giá bán : Vui lòng gọi

Số lượng:
Identify previously undetectable defects • Detect waveforms with high precision (200 MHz high speed sampling × high 12-bit resolution) • Identify single-fault turns via quantification of response waveforms into LC and RC values • Diagnose defective insulation (pseudo-shorts) between motor windings by testing for microscopic partial discharges hidden in noise (option)

Thông tin người bán

HIOKI VIỆT NAM

6 Hoa Ma, Hai Ba Trung, Ha Noi

Hotline: 0917047888

Email: hiokivietnam.vic@gmail.com

Thông số kỹ thuật

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement items • Quantification (LC value, RC value) of the response waveform obtained when impulse voltage is applied, pass / fail judgment
• Waveform judgment using AREA value, Flutter, Laplacian etc.
• Equipped with dielectric breakdown voltage test function
Applied voltage 100 V to 4200 V (Setting resolution: 10 V steps)
Maximum applied energy: approx. 88 mJ
Testable inductance range 10 μH to 100 mH
Sampling 200 M / 100 M / 50 M / 20 M / 10 MHz, Resolution: 12 bits, Number of data: 1001 to 800 points (1000 point steps)
Voltage detection accuracy [DC accuracy] ± 5% of setting, [AC band] 100 kHz: ± 1 dB
Determination method LC · RC value judgment, waveform judgment, discharge judgment (when incorporating the ST9000)
Number of test condition tables 255 (test condition setting, judgment condition setting, master waveform)
Test time About 60 ms (3000 V, 1 pulse, reference value at decision OFF)
Display 8.4-inch SVGA color TFT liquid crystal (800 × 600 dots), touch panel
Interface Standard:  EXT.I/O, USB host (memory), USB device (communication), LAN
Optional:  RS-232C (Z3001), GP-IB (Z3000)
Power supply 100 V to 240 V AC, 50/60 Hz, 80 VA max.
Dimensions and mass 215 mm (8.46 in)W × 200 mm (7.87 in)H × 348 mm (13.7 in)D, 6.7 kg (236.3 oz)
Accessories Power cord ×1, Instruction Manual ×1, Application disc ×1, Usage notes ×1

 

Options

Factory-installed option

Must specify when ordering

DISCHARGE DETECTION UPGRADE ST9000

• Detect microscopic partial discharges obscured by noise • HIOKI original filter

Learn more

Input/Output cords

Note: Effect of cable parasitic component

Vibration waveform changes according to cable length. For consultation on special order products with cable capacity within a certain range, please contact your Hioki distributor.

CLIP TYPE LEAD L2250

Max. rated voltage: 3300 V AC peak, 1.5 m (4.92 ft) length

 

UNPROCESSED LEAD CABLE L2252

Max. rated voltage: 4200 V AC peak, 2 m (6.56 ft) length

PC communication

GP-IB INTERFACE Z3000

 

 

RS-232C INTERFACE Z3001

 

 

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

 

RS-232C CABLE 9637

9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

Catalog sản phẩm

Bình chọn sản phẩm: (5.0 / 1 Bình chọn)

Thiết kế Web gian hàng chuyên nghiệp chỉ với 30 phút