| Ordering details | |
| Product type description | AZ 16-02ZVRK-ST - |
| Article number | 101143125 |
| EAN code | 4030661127224 |
| eCl@ss | 27-27-26-02 |
| Approval | |
| Approval |
BG
USA/CAN
CCC
|
| Classification | |
| Standards | EN ISO 13849-1 |
| B10d Normally-closed contact (NC) | 2.000.000 |
| Mission time | 20 Years |
| notice |
|
| Global Properties | |
| Product name | AZ 16 |
| Standards | EN 60947-5-1, BG-GS-ET-15 |
| Compliance with the Directives (Y/N)
| Yes |
| Materials | |
| - Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| - Material of the contacts | Silver |
| Housing coating | None |
| Weight | 120 g |
| Mechanical data | |
| Design of electrical connection | Connector M12 |
| Mechanical life | > 1.000.000 operations |
| higher Latching force (Y/N) | Yes |
| Latching force | 30 N |
| With ejection force (Y/N) | No |
| Positive break force | 20 N |
| positive break travel | 8 mm |
| Actuating speed | max. 2 m/s |
| Ambient conditions | |
| Ambient temperature | |
| - Min. environmental temperature | −30 °C |
| - Max. environmental temperature | +80 °C |
| Protection class | IP67 to IEC/EN 60529 |
| Electrical data | |
| Design of control element | Opener (NC) |
| Switching principle | Snap action with self-cleaning contact |
| Number of auxiliary contacts | 0 piece |
| Number of safety contacts | 2 piece |
| Rated impulse withstand voltage Uimp | 4 kV |
| Rated insulation voltage Ui | 500 V |
| Thermal test current Ithe | 10 A |
| Utilisation category | AC-15: 230 V / 4 A,DC-13: 24 V / 4 A |
| Max. fuse rating | 6 A gG D-fuse |
| ATEX | |
| Explosion protection categories for gases | None |
| Explosion protected category for dusts | None |
| Dimensions | |
| Dimensions of the sensor | |
| - Width of sensor | 52 mm |
| - Height of sensor | 90 mm |
| - Length of sensor | 30 mm |
| Included in delivery | |
| Actuators must be ordered separately. | |
| Diagram | |
Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact | |
| Switch travel diagram | |
Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angleVS adjustable range of NO contactVÖ adjustable range of NC contactN after travel | |
| Ordering suffix | |
| The applicable ordering suffix is added at the end of the part number of the safety switch.Order example: AZ 16-02ZVRK-ST-2254 | |
| ...-2254 | Latching force 5 N |
| ...L | Plug-in connection M12 left |
| ...R | Plug-in connection M12 right |
| ...-M20 | cable entries M20 |
| K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 WuppertalThe data and values have been checked throroughly. Technical modifications and errors excepted.Generiert am 11.06.2017 - 13:52:50h Kasbase 3.2.6.F.64I | |